Single Procedure
One operating procedure or SOP, drafted, reviewed, and operator-validated.
Quoted range $1,500–$2,500
OSHA PSM 1910.119(f) · EPA RMP
Gulf Coast water, wastewater, and chemical plants. Drafted from your documents, checked line by line, and quoted as a fixed price.
The work
Clear, numbered steps in the order the work is done, with operating limits, consequences of deviation, and safety systems where the operator needs them.
Every operating phase in 29 CFR 1910.119(f)(1)(i), and, where the process is RMP Program 3, the parallel list in 40 CFR 68.69(a)(1). Program 2 processes use 40 CFR 68.52, which is not the same text. Limits and equipment in the procedure are written so they can be traced to the process safety information.
AI-assisted drafting turns your existing procedures, drawings, and walkdown notes into a clean first draft in one format. Timing depends on how complete the file is, and on the review and walk-through that follow. Nothing is issued until that review is done.
Nothing is issued until it has been checked against your process safety information and walked through with your operators. Your subject-matter experts stay the approvers.
A covered process needs written instructions for each of these. A set that skips one is the finding that comes back.
Emergency shutdown includes the conditions that require it, and which qualified operators are responsible for carrying it out. Operating limits, consequences of deviation, and the steps to correct or avoid deviation are in 29 CFR 1910.119(f)(1)(ii). Where the process is RMP Program 3, the parallel phase list is 40 CFR 68.69(a)(1). Program 2 processes use 40 CFR 68.52, which is not the same text. The PSM phase list is 29 CFR 1910.119(f)(1)(i).
The problem
OSHA and EPA already require these procedures. A common finding is that the document does not match the way the covered process is actually run.
Steps out of order. Operating limits in an appendix. Consequences of deviation missing. The person at the equipment cannot use it, so they stop using it.
A valve, a setpoint, or a temporary lineup moved under management of change. The procedure still describes the old plant. Annual certification becomes a signature on a document no one trusts.
Missing phases — emergency shutdown, temporary operation, startup after a turnaround — return because rewriting the set keeps losing to the day’s work.
Packages
The figure you approve is a fixed quote, set after a scoping call. The ranges below are the bands those quotes fall in.
One operating procedure or SOP, drafted, reviewed, and operator-validated.
Quoted range $1,500–$2,500
Five related procedures in one consistent format. Best value for a unit or system.
Quoted range $6,500–$10,000
The complete operating-procedure set for one PSM- or RMP-covered process, all required phases.
Quoted range $12,000–$22,000
Up to 20 procedures kept current through the year, plus support for your annual certification. Your facility still performs that certification.
Quoted range $4,500–$9,000 / yr
Ranges shown. Your fixed quote depends on process complexity, the number of phases, and how complete the documentation is. Delivered in Word and PDF.
How it works
Current procedures, piping and instrumentation diagrams, process safety information, and a walkdown with your operators.
AI-assisted drafting produces a clean first draft from those documents and notes. Limits come from your process safety information.
Line-by-line technical review by the principal, then a walk-through with the people who run the equipment. Your experts remain the approvers.
Word and PDF, ready for the annual certification your facility performs. Critical Path Procedures does not certify the plant.
Who it's for
Where the work starts
Municipal systems with chlorine, ammonia, or sulfur dioxide equipment covered by the EPA Risk Management Program or OSHA PSM.
The same standard
Processes covered by OSHA PSM that need operating procedures written to 29 CFR 1910.119(f).
The buyer
People facing annual certification, an audit finding, or a backlog of management-of-change items that never made it into the SOP.
The corridor
Florida Panhandle, Alabama, Mississippi, and Louisiana. From Pensacola and Mobile across the corridor. Remote work is welcome.
The principal
Master Chief, U.S. Navy, Retired · B.A.S., Applied Science Technology · M.Ed., Educational Leadership
Greg Prichard spent about 24 years as a nuclear-field submariner in naval nuclear power plant operations, maintenance, and training. Those years were spent writing, running, and enforcing operating procedures, in a place where a procedure is followed exactly or the work stops.
He is now a senior manager in defense consulting. His education, in applied technology and in how people learn, is why a procedure is written the way an operator learns the work: numbered steps, in order, with the limit and the consequence on the step.
Critical Path Procedures writes and rewrites operating procedures for water, wastewater, and chemical facilities covered by OSHA Process Safety Management and the EPA Risk Management Program. It does not offer commercial nuclear power services. It is an independent business, not affiliated with or endorsed by the U.S. Navy, the Department of Defense, Naval Reactors, or any other U.S. government agency.
Insights
Short pieces on writing procedures operators can follow, and on what the rules actually say. All insights.
A procedure that does not match the work gets set aside. The fix is in how the page is written.
The operating-procedure rule is a list of elements, not a call for a thicker binder. Here is the list, in the order the text uses.
The people who run the unit already know the order of the work. The procedure's job is to capture that order and tie it to the process safety information.
Questions
A written operating procedure, or a set of them, in Word and PDF. Steps are numbered in the order the work is done. Where OSHA PSM applies, the set is written to cover the operating phases in 29 CFR 1910.119(f)(1)(i). Where EPA RMP Program 3 applies, it is aligned with 40 CFR 68.69; Program 2 processes use 40 CFR 68.52. Your operators walk through it before it is issued.
Your subject-matter experts remain the approvers of record. Critical Path Procedures drafts, reviews, and revises. The facility performs its own annual certification. Support on the retainer is help preparing for that certification. It is not a signature in place of yours.
A procedure built to the rule and checked against your process safety information is aimed at the usual finding: the written procedure does not match the covered process, or a required phase is missing. No one can promise an inspection outcome.
Drafting is AI-assisted, which is how a clean first draft can be produced from the procedures, drawings, and walkdown notes you already have. Timing depends on the file and on the review. Operating limits are taken from your process safety information. They are not guessed. Nothing is issued until the principal has checked it line by line and the people who run the equipment have walked through it.
Current procedures, piping and instrumentation diagrams, process safety information, and time with the operators for a walkdown. If the file is thin, say so on the scoping call. The quote depends on it.
The ranges on this page are bands, not a menu of flat fees. You receive a fixed quote after a scoping call. It depends on process complexity, the number of phases, and how complete the documentation is.
The practice is based in Pensacola, Florida. On-site work covers the Gulf Coast: the Florida Panhandle, Alabama, Mississippi, and Louisiana, from Pensacola and Mobile across the corridor. Remote work is welcome, including when a walkdown can be done with your people and the documents are in hand.
No. Greg Prichard is a retired Master Chief, U.S. Navy, and a nuclear-field submariner, and that is where the procedure discipline comes from. Critical Path Procedures does not offer commercial nuclear power services. It is an independent business, not affiliated with or endorsed by the U.S. Navy, the Department of Defense, Naval Reactors, or any other U.S. government agency.
Contact
Email for a scoping call and a fixed quote.
Greg Prichard
Principal, Critical Path Procedures LLC
greg@criticalpathprocedures.com
Pensacola, Florida